Show simple item record

dc.contributor.authorArias Velasquez, Ricardo Manuel
dc.contributor.authorArias Velasquez, Renato Fabricio
dc.date.accessioned2025-02-12T15:43:03Z
dc.date.available2025-02-12T15:43:03Z
dc.date.issued2025-02-12
dc.identifier.urihttps://hdl.handle.net/20.500.13067/3632
dc.description.abstractThis research article investigates the performance and fault detection capabilities of 35 zig-zag transformers connected to solar power plants in the medium voltage busbar, focusing on “dissolved gas analysis” (DGA) and fault diagnostics. Despite the absence of sudden disconnections, the transformers exhibited evolving failure modes. The study details the protection mechanisms employed, including overcurrent, overvoltage, and me chanical protections, integrated with a master trip system. Revealing significant deviations from normal levels before faults. Elevated hydrogen and methane levels, along with increased acetylene concentrations, indicated severe arcing and overheating, while treated oil samples showed a notable reduction in gas concentrations, underscoring the effectiveness of oil treatment in managing thermal and electrical stresses. This paper highlights the evolution of fault modes, including partial discharges, thermal faults, and arc faults, with specific diagnostic markers for each. The analysis of transient currents during faults indicated internal short circuits, leading to substantial mechanical and thermal damage, including core misalignment and tank deformation. The efficiency increases from 85.71 % in the detection with DGA to 91.43 % based on the combined analysis for DGA, comtrade and overcurrent analysis in the complete fleet.es_PE
dc.formatapplication/pdfes_PE
dc.language.isoenges_PE
dc.publisherScienceDirectes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/es_PE
dc.subjectDGAes_PE
dc.subjectOiles_PE
dc.subjectTransformeres_PE
dc.subjectZig-zages_PE
dc.titleEnhanced fault detection in zig-zag transformers: Insights from dissolved gas analysis and transient current analysises_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.identifier.journalResults in Engineeringes_PE
dc.identifier.doihttps://doi.org/10.1016/j.rineng.2025.104166
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#5.05.00es_PE
dc.publisher.countryPEes_PE
dc.source.volume25es_PE
dc.source.issue2025es_PE
dc.source.beginpage1es_PE
dc.source.endpage15es_PE